A server confined with --automation-read-root or
--automation-write-root has no plug-in store, so a grant accepted under
the flag could not be written to grants.json and recorded grants were
not read. mcp now refuses the combination at start-up.
The help text, docs/plugins.md and docs/mcp.md state that a confined
server does not install a module that lists permissions or asks for a
heavy budget, and that with VECTORCRAFT_NO_PREFS set a grant accepted
under the flag lasts for that session only.
plugin_grants_need_the_start_up_flag now drives `vectorcraft-cli mcp
--headless` over stdio. plugin.install with grant is refused without
--allow-plugin-grants and accepted with it.
The name field under Preset Details had no label and sat directly above the
Preset Name row, so it read as the name of the preset. It now has a Document
Name caption. Every catalog already translates that string.
An embedded image also comes with pixelsOmitted: true when its data is missing, its width or height is 0, its data cannot be decoded within the decoder's memory limit, or its dimensions differ from pixelSize. The entry tells plug-ins to check the flag before reading pixelsBase64.
A grant accepted under --allow-plugin-grants is written to grants.json like a
person's approval and counts as approved in later sessions and in the desktop
app. The CLI usage text, the plugin.install params text and docs/plugins.md and
docs/mcp.md said only a person's approval in the desktop app records one.
The Tools panel docked only on the left (the window's edge, or beside the
canvas with Keep Tools Beside the Canvas). Dropped on the canvas's right
edge, just left of the panels, or anywhere along the window's right edge,
it now docks on the right, between the canvas and the panels: it is drawn
inside the canvas panel at its right edge, which reserves room for it, so it
follows the panels however they are arranged. Dragged back to the left it
docks there again; Escape puts it back on the side it came from.
- The side is kept with the preferences and in saved workspaces (built-in
workspaces and state saved without it dock it on the left).
- Tool flyouts and the Edit Toolbar drawer open toward the canvas from a
toolbar docked right (toolbar::room / toolbar::beside).
- window.panel.dock {panel: "tools", side?: left|right (or Start|End)},
default the side it docked at last; replies carry the side. The grip's tip
names both edges; translated in every catalog.
- Test: the_tools_panel_docks_on_the_right_left_of_the_panels.
The fuzz test from #6223 passes grant to plugin.install, which a plain
session now refuses, so its cases stopped installing the module. The
docs line for a filter that lists inputs now says installing it needs a
person's approval.
Only a Stroke Style filter's widths written as one centered array come in as the drawn look. A Stroke Offset stroke and widths written for each side stay live with their profile.
Only a painted effect's references are checked, so a refusal recorded for a painted effect stayed in plugin.info after an effect that paints nothing replaced it under the same id.